----- Processed at : 21-Jul-2023 12:02:31 -----

1. The cytometric analysis is performed on machine IFREMER
2. The CytoUSB software used is CytoUSB Version: 5.11.1.25
3. The filename is FLR15 2023-04-19 07h59.cyz
4. The analysis is performed on 19-04-2023 time 08:00:58
5. The number of measured particles is 8615
6. The total concentration found (e.g. only SWS trigg.) is 28 particles/microliter
7. The concentration found (all used triggers) is 28 particles/microliter
8. The preconcentration (before analysis) found (all used triggers) is 81 particles/microliter
9. The flush time found (between samples) is 60 seconds
10. The effective analysis volume is 307.911 microliter
11. The pumped volume is 379.8 microliter
12. The particle-rate is 59 particles passing the laser beam/second
13. The used sample flow rate is 2.1106 microliter/second
14. The used block size memory is 4 kB
15. Trigger 1: FL Red at threshold level 15 mV
16. Trigger 2: not used at threshold level -999
17. Temperature sensor PMT is : 29.5 C
18. Temperature sensor Sheath is : 28.9 C
19. Temperature sensor Sheath is : 28.2 C
20. Temperature sensor System is : 26.0 C
21. Pressure sensor difference is : -270 mBar
22. Pressure sensor absolute is : 253 mBar
23. Sample pump 1: Last calibration of the sample pump was : 02-Févr-2023
24. Alignment check 1 by curvature detector is 0.75099 (1=perfect)
25. Alignment check 2 by curvature detector is 36% (100%=perfect)
26. Saturated signals (flattened peaks) occur when the dynamic range of the (HS)detector is reached
27. FWS: Nr of saturated signals is 0 (0% of 8615 measured particles)
28. FWS: Maximum signal height found is 1013 mV
29. FWS: Nr of particles with signal height <10 mV is high (46 part. (1 %))
30. SWS HS: Nr of saturated signals is 17 (0% of 8615 measured particles)
31. SWS HS: Maximum signal height found is 5000 mV
32. SWS HS: Nr of particles with signal height <10 mV is high (56 part. (1 %))
33. FL Red HS: Nr of saturated signals is 0 (0% of 8615 measured particles)
34. FL Red HS: Maximum signal height found is 3781 mV
35. FL Red HS: Nr of particles with signal height <10 mV is high (9 part. (0 %))
36. FL Yellow HS: Nr of saturated signals is 0 (0% of 8615 measured particles)
37. FL Yellow HS: Maximum signal height found is 35 mV
38. FL Yellow HS: Nr of particles with signal height <10 mV is high (8612 part. (100 %))
39. FL Orange HS: Nr of saturated signals is 0 (0% of 8615 measured particles)
40. FL Orange HS: Maximum signal height found is 321 mV
41. FL Orange HS: Nr of particles with signal height <10 mV is high (8598 part. (100 %))
42. FL Green HS: Nr of saturated signals is 0 (0% of 8615 measured particles)
43. FL Green HS: Maximum signal height found is 101 mV
44. FL Green HS: Nr of particles with signal height <10 mV is high (8613 part. (100 %))
45. FWS: Nr of block shaped signals is 15 (0.17411%)
46. SWS HS: Nr of block shaped signals is 13 (0.1509%)
47. FL Red HS: Nr of block shaped signals is 1 (0.011608%)
48. Suspect nr: 0=low, 10=high
49. Maximum FWS: suspect = 0
50. Maximum SWS HS: suspect = 1
51. Maximum FL Red HS: suspect = 0
52. Maximum FL Yellow HS: suspect = 0
53. Maximum FL Orange HS: suspect = 0
54. Maximum FL Green HS: suspect = 3
55. SWS: PMT level is 60
56. FL Red: PMT level is 85
57. FL Yellow: PMT level is 90
58. FL Orange: PMT level is 85
59. FL Green: PMT level is 85

-------------------------- Warnings info --------------------------
1.01 Warning: The number of saved particles in this analysis is quite low and
1.01 Warning: you might miss (statistically) bigger particles in your sample
1.01.1 Solution - Increase number of measured particles. Increase setted time OR after setted number of analyzed particles (in CytoUSB)
1.03 Warning: Your preconcentration differs more than 25% from the during analysis concentration
1.03.1 Solution - Carry over between samples? > Flush longer
1.03.2 Solution - Better homogenize samples during subsampling by a gentle stirrer
1.03.3 Solution - Colonies-filaments of cells break during analysis > stir slower
1.09 Warning: This (default) low block size of 4kB in CytoUSB will decrease the effective analysis volume. (Only older CytoSenses)
1.09.1 Solution - Increase block size memory if the total particle rate is high enough (but prevent time outs) OR set to 'auto'
1.23 Warning: FWS-L and -R might indicate an air bubble problem 36% (100%=perfect)
1.23.1 Solution - Pinch valve to get rid of the air bubble or blockage by something different
1.26 Warning: FL Yellow HS: Biggest particles found is only 35 mV. Detector sensitivity might be too low.
1.26.1 Solution - Increase, set higher FL Yellow HS PMT voltage in CytoUSB (make more sensitive)
1.27 Warning: FL Yellow HS : Nr of particles with signal height <10 mV is high (100 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.26 Warning: FL Orange HS: Biggest particles found is only 321 mV. Detector sensitivity might be too low.
1.26.1 Solution - Increase, set higher FL Orange HS PMT voltage in CytoUSB (make more sensitive)
1.27 Warning: FL Orange HS : Nr of particles with signal height <10 mV is high (100 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.26 Warning: FL Green HS: Biggest particles found is only 101 mV. Detector sensitivity might be too low.
1.26.1 Solution - Increase, set higher FL Green HS PMT voltage in CytoUSB (make more sensitive)
1.27 Warning: FL Green HS : Nr of particles with signal height <10 mV is high (100 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.25 Warning: Suspected particles data blocks found!
1.29.1: Maximum FL Green HS: suspect = 3
1.29.11 Solution - Particle rate too high?
1.29.21 Solution - Trigger too sensitive?
1.29.31 Solution - Details look at 'DATA DIAGNOSIS' in 'Check CytoSense-Diagnosis-Meta Data'
Disclaimer
Any use of the provided data and results or information provided by this website is on full own risk and responsibility. Those who gave access to this website or those who provided the results represented on the website cannot be held responsible for any damage or consequences that could arise from the use of this information. This LIVE system is empowered by the Rijkswaterstaat, CytoBuoy BV and Thomas Rutten Projects. TRP Copyright 2020