EasyClus check & Info of last file

----- Processed at : 08-Jul-2024 20:22:51 -----

1. The cytometric analysis is performed on machine LOG I
2. The CytoBuoy instrument serial-nr is CS-2019-93
3. The CytoUSB software used is CytoUSB Version: 5.11.1.6
4. The filename is SeineMO_Pico_continu_flr3_5ul_8min 2024-05-07 19h09.cyz
5. The analysis is performed on 07-05-2024 time 19:10:14
6. The number of measured particles is 206807
7. The total concentration found (e.g. only SWS trigg.) is 86 particles/microliter
8. The concentration found (all used triggers) is 86 particles/microliter
9. The preconcentration (before analysis) found (all used triggers) is 86 particles/microliter
10. The flush time found (between samples) is 50 seconds
11. The effective analysis volume is 2413.2837 microliter
12. The pumped volume is 2419.2 microliter
13. The particle-rate is 432 particles passing the laser beam/second
14. The used sample flow rate is 5.0417 microliter/second
15. Trigger 1: FL Red at threshold level 3 mV
16. Trigger 2: not used at threshold level -999
17. Temperature sensor PMT is : 29.6 C
18. Temperature sensor Sheath is : 28.2 C
19. Temperature sensor Laser is : 27.4 C
20. Temperature sensor System is : 24.5 C
21. Pressure sensor difference is : -392 mBar
22. Pressure sensor absolute is : 261 mBar
23. Sample pump 1: Last calibration of the sample pump was : 25-Mar-2024
24. Alignment check 1 by curvature detector is 0.7646 (1=perfect)
25. Alignment check 2 by curvature detector is 34.1% (>70%=perfect)
26. Saturated signals (flattened peaks) occur when the dynamic range of the (HS)detector is reached
27. FWS: Nr of saturated signals is 6 (0% of 206807 measured particles)
28. FWS: Maximum signal height found is 14848 mV
29. FWS: Nr of particles with signal height <10 mV is high (147933 part. (72 %))
30. SWS HS: Nr of saturated signals is 4631 (0% of 206807 measured particles)
31. SWS HS: Maximum signal height found is 7488 mV
32. SWS HS: Nr of particles with signal height <10 mV is high (109313 part. (53 %))
33. FL Yellow HS: Nr of saturated signals is 1 (0% of 206807 measured particles)
34. FL Yellow HS: Maximum signal height found is 5504 mV
35. FL Yellow HS: Nr of particles with signal height <10 mV is high (204090 part. (99 %))
36. FL Orange HS: Nr of saturated signals is 1 (0% of 206807 measured particles)
37. FL Orange HS: Maximum signal height found is 6784 mV
38. FL Orange HS: Nr of particles with signal height <10 mV is high (204267 part. (99 %))
39. FL Red HS: Nr of saturated signals is 80 (0% of 206807 measured particles)
40. FL Red HS: Maximum signal height found is 7488 mV
41. FL Red HS: Nr of particles with signal height <10 mV is high (146928 part. (71 %))
42. SWS HS: Nr of block shaped signals is 3829 (1.8515%)
43. FWS: Nr of block shaped signals is 2055 (0.99368%)
44. FL Yellow HS: Nr of block shaped signals is 5 (0.0024177%)
45. FL Red HS: Nr of block shaped signals is 1 (0.00048354%)
46. Suspect nr: 0=low, 10=high
47. Maximum FWS: suspect = 0
48. Maximum SWS HS: suspect = 0
49. Maximum FL Yellow HS: suspect = 0
50. Maximum FL Orange HS: suspect = 0
51. Maximum FL Red HS: suspect = 0
52. SWS: PMT level is 60
53. FL Yellow: PMT level is 90
54. Fl Orange: PMT level is 85
55. FL Red: PMT level is 85

-------------------------- Warnings info --------------------------
1.02 Warning: The number of saved particles in this analysis is quite high
1.02 Warning: Is it really necessary to store so many particles? E.g. data processing will take longer
1.02.1 Solution - Do not stop analysis after setted time, but after setted number of analyzed particles (in CytoUSB)
1.04 Warning: Your flush time (50 seconds) is quite small
1.04.1 Solution - Flush longer e.g. 80 sec.
1.10 Warning: This threshold level is quite low and near noise
1.10 Warning: Take care you don't measure noise or in noise (this will give high particle rates but is in fact noise)
1.10.1 Solution - Increase threshold trigger level
1.23 Warning: Percentage ratio FWS-L/-R data within bandwidth is small which might indicate an alignment problem 34.1% (>70%=perfect)
1.23.1 Solution - Maybe an air bubble or blockage problem? Pinch valve to get rid of the air bubble or blockage by something different
1.27 Warning: FWS : Nr of particles with signal height <10 mV is high (72 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: SWS HS : Nr of particles with signal height <10 mV is high (53 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: FL Yellow HS : Nr of particles with signal height <10 mV is high (99 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: FL Orange HS : Nr of particles with signal height <10 mV is high (99 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: FL Red HS : Nr of particles with signal height <10 mV is high (71 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
Disclaimer
Any use of the provided data and results or information provided by this website is on full own risk and responsibility. Those who gave access to this website or those who provided the results represented on the website cannot be held responsible for any damage or consequences that could arise from the use of this information. This LIVE system is empowered by the organization in the tab, CytoBuoy BV and Thomas Rutten Projects. TRP © 2022