Live Results FRAM24_PS143_2
To overview 2
EasyClus check & Info of last file

----- Processed at : 05-Aug-2024 06:02:45 -----

1. The cytometric analysis is performed on machine LOG II
2. The CytoBuoy instrument serial-nr is CS-2019-94
3. The CytoUSB software used is CytoUSB Version: 5.11.1.6
4. The filename is cont-pico_flr02.00_05uls_03min 2024-08-05 05h59.cyz
5. The analysis is performed on 05-08-2024 time 05:59:23
6. The number of measured particles is 14041
7. The total concentration found (e.g. only SWS trigg.) is 16 particles/microliter
8. The concentration found (all used triggers) is 16 particles/microliter
9. The preconcentration (before analysis) found (all used triggers) is 16 particles/microliter
10. The flush time found (between samples) is 40 seconds
11. The effective analysis volume is 894.8068 microliter
12. The pumped volume is 896.4 microliter
13. The particle-rate is 78 particles passing the laser beam/second
14. The used sample flow rate is 4.9817 microliter/second
15. Trigger 1: FL Red at threshold level 2 mV
16. Trigger 2: not used at threshold level -999
17. Temperature sensor PMT is : 31.5 C
18. Temperature sensor Sheath is : 30.6 C
19. Temperature sensor Laser is : 30.4 C
20. Temperature sensor System is : 27.7 C
21. Pressure sensor difference is : -335 mBar
22. Pressure sensor absolute is : 317 mBar
23. Sample pump 1: Last calibration of the sample pump was : 14-Apr-2022
24. Alignment check 1 by curvature detector is 0.80129 (1=perfect)
25. Alignment check 2 by curvature detector is 80.3% (>70%=perfect)
26. Saturated signals (flattened peaks) occur when the dynamic range of the (HS)detector is reached
27. FWS: Nr of saturated signals is 1 (0% of 14041 measured particles)
28. FWS: Maximum signal height found is 14944 mV
29. FWS: Nr of particles with signal height <10 mV is high (575 part. (4 %))
30. SWS HS: Nr of saturated signals is 44 (0% of 14041 measured particles)
31. SWS HS: Maximum signal height found is 7616 mV
32. SWS HS: Nr of particles with signal height <10 mV is high (171 part. (1 %))
33. FL Yellow HS: Nr of saturated signals is 0 (0% of 14041 measured particles)
34. FL Yellow HS: Maximum signal height found is 512 mV
35. FL Yellow HS: Nr of particles with signal height <10 mV is high (13815 part. (98 %))
36. FL Orange HS: Nr of saturated signals is 0 (0% of 14041 measured particles)
37. FL Orange HS: Maximum signal height found is 312 mV
38. FL Orange HS: Nr of particles with signal height <10 mV is high (13948 part. (99 %))
39. FL Red HS: Nr of saturated signals is 1 (0% of 14041 measured particles)
40. FL Red HS: Maximum signal height found is 5696 mV
41. FL Red HS: Nr of particles with signal height <10 mV is high (7657 part. (55 %))
42. SWS HS: Nr of block shaped signals is 102 (0.72644%)
43. FWS: Nr of block shaped signals is 70 (0.49854%)
44. FL Yellow HS: Nr of block shaped signals is 1 (0.007122%)
45. Suspect nr: 0=low, 10=high
46. Maximum FWS: suspect = 0
47. Maximum SWS HS: suspect = 0
48. Maximum FL Yellow HS: suspect = 3
49. Maximum FL Orange HS: suspect = 3
50. Maximum FL Red HS: suspect = 0
51. SWS: PMT level is 60
52. FL Yellow: PMT level is 90
53. Fl Orange: PMT level is 85
54. FL Red: PMT level is 85

-------------------------- Warnings info --------------------------
1.04 Warning: Your flush time (40 seconds) is quite small
1.04.1 Solution - Flush longer e.g. 80 sec.
1.10 Warning: This threshold level is quite low and near noise
1.10 Warning: Take care you don't measure noise or in noise (this will give high particle rates but is in fact noise)
1.10.1 Solution - Increase threshold trigger level
1.21 Warning: Last calibration of sample pump towards analysis date was more than 90 days. (14-Apr-2022)
1.21.1 Solution - Check if the pumped analysis volume is the real volume by weighing
1.27 Warning: FL Yellow HS : Nr of particles with signal height <10 mV is high (98 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.26 Warning: FL Orange HS: Biggest particles found is only 312 mV. Detector sensitivity might be too low.
1.26.1 Solution - Increase, set higher FL Orange HS PMT voltage in CytoUSB (make more sensitive)
1.27 Warning: FL Orange HS : Nr of particles with signal height <10 mV is high (99 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: FL Red HS : Nr of particles with signal height <10 mV is high (55 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.25 Warning: Suspected particles data blocks found!
1.29.1: Maximum FL Yellow HS: suspect = 3
1.29.11 Solution - Particle rate too high?
1.29.21 Solution - Trigger too sensitive?
1.29.31 Solution - Details look at 'DATA DIAGNOSIS' in 'Check CytoSense-Diagnosis-Meta Data'
1.29.2: Maximum FL Orange HS: suspect = 3
1.29.12 Solution - Particle rate too high?
1.29.22 Solution - Trigger too sensitive?
1.29.32 Solution - Details look at 'DATA DIAGNOSIS' in 'Check CytoSense-Diagnosis-Meta Data'
Disclaimer
Any use of the provided data and results or information provided by this website is on full own risk and responsibility. Those who gave access to this website or those who provided the results represented on the website cannot be held responsible for any damage or consequences that could arise from the use of this information. This LIVE system is empowered by the organization in the tab, CytoBuoy BV and Thomas Rutten Projects. TRP © 2022