Live Results FRAM24_PS143_2-micro
To overview 2
EasyClus check & Info of last file

----- Processed at : 05-Aug-2024 06:10:14 -----

1. The cytometric analysis is performed on machine LOG II
2. The CytoBuoy instrument serial-nr is CS-2019-94
3. The CytoUSB software used is CytoUSB Version: 5.11.1.6
4. The filename is cont-micro_sws14_07uls_07min_sflr16max 2024-08-05 06h02.cyz
5. The analysis is performed on 05-08-2024 time 06:02:48
6. The number of measured particles is 14999
7. The total concentration found (e.g. only SWS trigg.) is 226 particles/microliter
8. The concentration found (all used triggers) is 5 particles/microliter
9. The preconcentration (before analysis) found (all used triggers) is 5 particles/microliter
10. The flush time found (between samples) is 40 seconds
11. The effective analysis volume is 2930.4796 microliter
12. The pumped volume is 2948.4 microliter
13. The particle-rate is 1586 particles passing the laser beam/second
14. The used sample flow rate is 7.0242 microliter/second
15. Trigger 1: SWS at threshold level 14 mV
16. Trigger 2: Maximum FL Red at threshold level 16
17. Temperature sensor PMT is : 31.5 C
18. Temperature sensor Sheath is : 30.6 C
19. Temperature sensor Laser is : 30.4 C
20. Temperature sensor System is : 27.7 C
21. Pressure sensor difference is : -335 mBar
22. Pressure sensor absolute is : 324 mBar
23. Sample pump 1: Last calibration of the sample pump was : 14-Apr-2022
24. Alignment check 1 by curvature detector is 0.83843 (1=perfect)
25. Alignment check 2 by curvature detector is 74.6% (>70%=perfect)
26. Saturated signals (flattened peaks) occur when the dynamic range of the (HS)detector is reached
27. FWS: Nr of saturated signals is 7 (0% of 14999 measured particles)
28. FWS: Maximum signal height found is 15104 mV
29. FWS: Nr of particles with signal height <10 mV is high (68 part. (0 %))
30. SWS HS: Nr of saturated signals is 116 (0% of 14999 measured particles)
31. SWS HS: Maximum signal height found is 7616 mV
32. SWS HS: Nr of particles with signal height <10 mV is high (0 part. (0 %))
33. FL Yellow HS: Nr of saturated signals is 0 (0% of 14999 measured particles)
34. FL Yellow HS: Maximum signal height found is 752 mV
35. FL Yellow HS: Nr of particles with signal height <10 mV is high (14811 part. (99 %))
36. FL Orange HS: Nr of saturated signals is 0 (0% of 14999 measured particles)
37. FL Orange HS: Maximum signal height found is 1712 mV
38. FL Orange HS: Nr of particles with signal height <10 mV is high (14756 part. (98 %))
39. FL Red HS: Nr of saturated signals is 0 (0% of 14999 measured particles)
40. FL Red HS: Maximum signal height found is 4000 mV
41. FL Red HS: Nr of particles with signal height <10 mV is high (0 part. (0 %))
42. FWS: Nr of block shaped signals is 1 (0.0066671%)
43. SWS HS: Nr of block shaped signals is 1 (0.0066671%)
44. FL Red HS: Nr of block shaped signals is 1 (0.0066671%)
45. Suspect nr: 0=low, 10=high
46. Maximum FWS: suspect = 0
47. Maximum SWS HS: suspect = 0
48. Maximum FL Yellow HS: suspect = 2
49. Maximum FL Orange HS: suspect = 3
50. Maximum FL Red HS: suspect = 0
51. SWS: PMT level is 60
52. FL Yellow: PMT level is 90
53. Fl Orange: PMT level is 85
54. FL Red: PMT level is 85

-------------------------- Warnings info --------------------------
1.04 Warning: Your flush time (40 seconds) is quite small
1.04.1 Solution - Flush longer e.g. 80 sec.
1.21 Warning: Last calibration of sample pump towards analysis date was more than 90 days. (14-Apr-2022)
1.21.1 Solution - Check if the pumped analysis volume is the real volume by weighing
1.27 Warning: FL Yellow HS : Nr of particles with signal height <10 mV is high (99 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: FL Orange HS : Nr of particles with signal height <10 mV is high (98 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.25 Warning: Suspected particles data blocks found!
1.29.1: Maximum FL Orange HS: suspect = 3
1.29.11 Solution - Particle rate too high?
1.29.21 Solution - Trigger too sensitive?
1.29.31 Solution - Details look at 'DATA DIAGNOSIS' in 'Check CytoSense-Diagnosis-Meta Data'
Disclaimer
Any use of the provided data and results or information provided by this website is on full own risk and responsibility. Those who gave access to this website or those who provided the results represented on the website cannot be held responsible for any damage or consequences that could arise from the use of this information. This LIVE system is empowered by the organization in the tab, CytoBuoy BV and Thomas Rutten Projects. TRP © 2022