Live Results CGFS
To overview 2
EasyClus check & Info of last file

----- Processed at : 17-Oct-2022 02:01:04 -----

1. The cytometric analysis is performed on machine LOG I
2. The CytoUSB software used is CytoUSB Version: 5.11.1.6
3. The filename is CGFS-continu_flr3_5ul_8min 2022-10-16 13h39.cyz
4. The analysis is performed on 16-10-2022 time 13:39:28
5. The number of measured particles is 59401
6. The total concentration found (e.g. only SWS trigg.) is 29 particles/microliter
7. The concentration found (all used triggers) is 29 particles/microliter
8. The preconcentration (before analysis) found (all used triggers) is 29 particles/microliter
9. The flush time found (between samples) is 60 seconds
10. The effective analysis volume is 2066.0523 microliter
11. The pumped volume is 2068.8 microliter
12. The particle-rate is 124 particles passing the laser beam/second
13. The used sample flow rate is 4.3129 microliter/second
14. The used block size memory is 4 kB
15. Trigger 1: FL Red at threshold level 3 mV
16. Trigger 2: not used at threshold level -999
17. Temperature sensor PMT is : 26.8 C
18. Temperature sensor Sheath is : 25.9 C
19. Temperature sensor Sheath is : 24.4 C
20. Temperature sensor System is : 21.2 C
21. Pressure sensor difference is : -285 mBar
22. Pressure sensor absolute is : 136 mBar
23. Sample pump 1: Last calibration of the sample pump was : 07-Mar-2022
24. Alignment check 1 by curvature detector is NaN (1=perfect)
25. Alignment check 2 by curvature detector is 0% (100%=perfect)
26. Saturated signals (flattened peaks) occur when the dynamic range of the (HS)detector is reached
27. FWS: Nr of saturated signals is 1 (0% of 59401 measured particles)
28. FWS: Maximum signal height found is 14720 mV
29. FWS: Nr of particles with signal height <10 mV is high (10514 part. (18 %))
30. SWS HS: Nr of saturated signals is 4918 (0% of 59401 measured particles)
31. SWS HS: Maximum signal height found is 7488 mV
32. SWS HS: Nr of particles with signal height <10 mV is high (6089 part. (10 %))
33. FL Yellow HS: Nr of saturated signals is 1 (0% of 59401 measured particles)
34. FL Yellow HS: Maximum signal height found is 6432 mV
35. FL Yellow HS: Nr of particles with signal height <10 mV is high (46291 part. (78 %))
36. FL Orange HS: Nr of saturated signals is 1 (0% of 59401 measured particles)
37. FL Orange HS: Maximum signal height found is 7456 mV
38. FL Orange HS: Nr of particles with signal height <10 mV is high (51007 part. (86 %))
39. FL Red HS: Nr of saturated signals is 10 (0% of 59401 measured particles)
40. FL Red HS: Maximum signal height found is 7488 mV
41. FL Red HS: Nr of particles with signal height <10 mV is high (24141 part. (41 %))
42. SWS HS: Nr of block shaped signals is 4038 (6.7979%)
43. FWS: Nr of block shaped signals is 2326 (3.9158%)
44. FL Yellow HS: Nr of block shaped signals is 3 (0.0050504%)
45. Suspect nr: 0=low, 10=high
46. Maximum FWS: suspect = 0
47. Maximum SWS HS: suspect = 0
48. Maximum FL Yellow HS: suspect = 1
49. Maximum FL Orange HS: suspect = 1
50. Maximum FL Red HS: suspect = 0
51. SWS: PMT level is 60
52. FL Yellow: PMT level is 90
53. Fl Orange: PMT level is 85
54. FL Red: PMT level is 85

-------------------------- Warnings info --------------------------
1.09 Warning: This (default) low block size of 4kB in CytoUSB will decrease the effective analysis volume. (Only older CytoSenses)
1.09.1 Solution - Increase block size memory if the total particle rate is high enough (but prevent time outs) OR set to 'auto'
1.10 Warning: This threshold level is quite low and near noise
1.10 Warning: Take care you don't measure noise or in noise (this will give high particle rates but is in fact noise)
1.10.1 Solution - Increase threshold trigger level
1.21 Warning: Last calibration of sample pump towards analysis date was more than 90 days. (07-Mar-2022)
1.21.1 Solution - Check if the pumped analysis volume is the real volume by weighing
1.23 Warning: FWS-L and -R might indicate an air bubble problem 0% (100%=perfect)
1.23.1 Solution - Pinch valve to get rid of the air bubble or blockage by something different
1.27 Warning: FL Yellow HS : Nr of particles with signal height <10 mV is high (78 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: FL Orange HS : Nr of particles with signal height <10 mV is high (86 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.28 Warning: SWS HS: A relative large amount of particles are (rather) block shaped (7%)
1.28.1 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.28.2 Solution - Decrease, set lower SWS HS PMT voltage in CytoUSB (make less sensitive)
Disclaimer
Any use of the provided data and results or information provided by this website is on full own risk and responsibility. Those who gave access to this website or those who provided the results represented on the website cannot be held responsible for any damage or consequences that could arise from the use of this information. This LIVE system is empowered by the ULCO-CNRS, CytoBuoy BV and Thomas Rutten Projects. TRP Copyright 2023