Live Results Test
To overview 2


----- Processed at : 10-Jul-2024 15:47:35 -----

1. The cytometric analysis is performed on machine RWS Systeem 2
2. The CytoBuoy instrument serial-nr is CS-2019-92
3. The CytoUSB software used is CytoUSB Version: 5.8.3.31
4. The filename is CS_2019_92_prot_2 2022-01-27 14h31.cyz
5. The analysis is performed on 27-01-2022 time 14:31:36
6. The number of measured particles is 4587
7. The total concentration found (e.g. only SWS trigg.) is 1562 particles/microliter
8. The concentration found (all used triggers) is 8 particles/microliter
9. The preconcentration (before analysis) found (all used triggers) is 8 particles/microliter
10. The flush time found (between samples) is 130 seconds
11. The effective analysis volume is 567.7529 microliter
12. The pumped volume is 573 microliter
13. The particle-rate is 2990 particles passing the laser beam/second
14. The used sample flow rate is 1.9134 microliter/second
15. Trigger 1: SWS HS at threshold level 15 mV
16. Trigger 2: Maximum FL Red HS at threshold level 6
17. Temperature sensor PMT is : 32.2 C
18. Temperature sensor Sheath is : 31.7 C
19. Temperature sensor Laser is : 30.9 C
20. Temperature sensor System is : 26.7 C
21. Pressure sensor difference is : -226 mBar
22. Pressure sensor absolute is : 177 mBar
23. Sample pump 1: Last calibration of the sample pump was : 16-Feb-2021
24. Alignment check 1 by curvature detector is 0.73385 (1=perfect)
25. Alignment check 2 by curvature detector is 29.6% (>70%=perfect)
26. Saturated signals (flattened peaks) occur when the dynamic range of the (HS)detector is reached
27. FWS: Nr of saturated signals is 1 (0% of 4587 measured particles)
28. FWS: Maximum signal height found is 14848 mV
29. FWS: Nr of particles with signal height <10 mV is high (1 part. (0 %))
30. SWS HS: Nr of saturated signals is 6 (0% of 4587 measured particles)
31. SWS HS: Maximum signal height found is 7488 mV
32. SWS HS: Nr of particles with signal height <10 mV is high (0 part. (0 %))
33. FL Yellow HS: Nr of saturated signals is 1 (0% of 4587 measured particles)
34. FL Yellow HS: Maximum signal height found is 7360 mV
35. FL Yellow HS: Nr of particles with signal height <10 mV is high (2904 part. (63 %))
36. FL Orange HS: Nr of saturated signals is 1 (0% of 4587 measured particles)
37. FL Orange HS: Maximum signal height found is 7360 mV
38. FL Orange HS: Nr of particles with signal height <10 mV is high (3623 part. (79 %))
39. FL Red HS: Nr of saturated signals is 1 (0% of 4587 measured particles)
40. FL Red HS: Maximum signal height found is 6496 mV
41. FL Red HS: Nr of particles with signal height <10 mV is high (1350 part. (29 %))
42. SWS HS: Nr of block shaped signals is 1 (0.021801%)
43. Suspect nr: 0=low, 10=high
44. Maximum FWS: suspect = 0
45. Maximum SWS HS: suspect = 1
46. Maximum SWS LS: suspect = 2
47. Maximum FL Yellow HS: suspect = 0
48. Maximum FL Yellow LS: suspect = 3
49. Maximum FL Orange HS: suspect = 3
50. Maximum FL Red HS: suspect = 2
51. Maximum FL Red LS: suspect = 2
52. SWS HS: PMT level is 56
53. SWS LS: PMT level is 46
54. FL Yellow HS: PMT level is 85
55. FL Yellow LS: PMT level is 68
56. Fl Orange: PMT level is 79
57. FL Red HS: PMT level is 110
58. FL Red LS: PMT level is 91
59. IIF: Imaging in Flow pictures available. Nr of images is 886

-------------------------- Warnings info --------------------------
1.01 Warning: The number of saved particles in this analysis is quite low and
1.01 Warning: you might miss (statistically) bigger particles in your sample
1.01.1 Solution - Increase number of measured particles. Increase setted time OR after setted number of analyzed particles (in CytoUSB)
1.07 Warning: Analysis with high particle rate (2990), meaning you have higher chance of coincidence
1.07.1 Solution - Decrease, use lower sample rate
1.07.2 Solution - Is threshold in noise level? Increase threshold and find out of particle rate is suddenly lower and quite stable
1.07.3 Solution - Is the sheath fluid clean enough?
1.21 Warning: Last calibration of sample pump towards analysis date was more than 90 days. (16-Feb-2021)
1.21.1 Solution - Check if the pumped analysis volume is the real volume by weighing
1.23 Warning: Percentage ratio FWS-L/-R data within bandwidth is small which might indicate an alignment problem 29.6% (>70%=perfect)
1.23.1 Solution - Maybe an air bubble or blockage problem? Pinch valve to get rid of the air bubble or blockage by something different
1.24 Warning: SWS LS: Maximum is 247 mV if HS is around 4500 mV and too high.
1.24.1 Solution - Put LS PMT lower. Maximum LS around 50 mV (if HS is around 4500 mV).
1.24 Warning: SWS LS: HS-LS ratio is 48 and too low.
1.24.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.24 Warning: FL Red LS: HS-LS ratio is 24 and too low.
1.24.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.27 Warning: FL Yellow HS : Nr of particles with signal height <10 mV is high (63 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: FL Orange HS : Nr of particles with signal height <10 mV is high (79 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.25 Warning: Suspected particles data blocks found!
1.29.1: Maximum FL Yellow LS: suspect = 3
1.29.11 Solution - Particle rate too high?
1.29.21 Solution - Trigger too sensitive?
1.29.31 Solution - Details look at 'DATA DIAGNOSIS' in 'Check CytoSense-Diagnosis-Meta Data'
1.29.2: Maximum FL Orange HS: suspect = 3
1.29.12 Solution - Particle rate too high?
1.29.22 Solution - Trigger too sensitive?
1.29.32 Solution - Details look at 'DATA DIAGNOSIS' in 'Check CytoSense-Diagnosis-Meta Data'
Disclaimer
Any use of the provided data and results or information provided by this website is on full own risk and responsibility. Those who gave access to this website or those who provided the results represented on the website cannot be held responsible for any damage or consequences that could arise from the use of this information. This LIVE system is empowered by the organization in the tab, CytoBuoy BV and Thomas Rutten Projects. TRP © 2022