EasyClus check & Info of last file

----- Processed at : 29-Nov-2021 12:30:14 -----

1. The cytometric analysis is performed on machine Markermeer
2. The CytoUSB software used is CytoUSB Version: 5.9.4.4
3. The filename is CS2019-91 MW beads 2021-11-29 12h18.cyz
4. The analysis is performed on 29-11-2021 time 12:18:54
5. The number of measured particles is 11740
6. The total concentration found (e.g. only SWS trigg.) is 741 particles/microliter
7. The concentration found (all used triggers) is 38 particles/microliter
8. The preconcentration (before analysis) found (all used triggers) is 38 particles/microliter
9. The flush time found (between samples) is 130 seconds
10. The effective analysis volume is 305.6026 microliter
11. The pumped volume is 308.4 microliter
12. The particle-rate is 1908 particles passing the laser beam/second
13. The used sample flow rate is 2.573 microliter/second
14. The used block size memory is 4 kB
15. Trigger 1: SWS HS at threshold level 15 mV
16. Trigger 2: Maximum FL Red HS at threshold level 6
17. Temperature sensor PMT is : 10.0 C
18. Temperature sensor Sheath is : 8.9 C
19. Temperature sensor Sheath is : 9.2 C
20. Temperature sensor System is : 7.1 C
21. Pressure sensor difference is : -299 mBar
22. Pressure sensor absolute is : 349 mBar
23. External battery Voltage is : 13.0 Volt
24. Sample pump 1: Last calibration of the sample pump was : 24-Feb-2021
25. Alignment check 1 by curvature detector is 1.0522 (1=perfect)
26. Alignment check 2 by curvature detector is 98% (100%=perfect)
27. Saturated signals (flattened peaks) occur when the dynamic range of the (HS)detector is reached
28. FWS: Nr of saturated signals is 1 (0% of 11740 measured particles)
29. FWS: Maximum signal height found is 12416 mV
30. FWS: Nr of particles with signal height <10 mV is high (250 part. (2 %))
31. SWS HS: Nr of saturated signals is 2 (0% of 11740 measured particles)
32. SWS HS: Maximum signal height found is 7360 mV
33. SWS HS: Nr of particles with signal height <10 mV is high (0 part. (0 %))
34. FL Yellow HS: Nr of saturated signals is 1 (0% of 11740 measured particles)
35. FL Yellow HS: Maximum signal height found is 7360 mV
36. FL Yellow HS: Nr of particles with signal height <10 mV is high (8453 part. (72 %))
37. FL Orange HS: Nr of saturated signals is 0 (0% of 11740 measured particles)
38. FL Orange HS: Maximum signal height found is 2592 mV
39. FL Orange HS: Nr of particles with signal height <10 mV is high (7656 part. (65 %))
40. FL Red HS: Nr of saturated signals is 3 (0% of 11740 measured particles)
41. FL Red HS: Maximum signal height found is 7360 mV
42. FL Red HS: Nr of particles with signal height <10 mV is high (4455 part. (38 %))
43. FL Red HS: Nr of block shaped signals is 26 (0.22147%)
44. SWS HS: Nr of block shaped signals is 22 (0.18739%)
45. FWS: Nr of block shaped signals is 16 (0.13629%)
46. FL Orange HS: Nr of block shaped signals is 4 (0.034072%)
47. FL Yellow HS: Nr of block shaped signals is 2 (0.017036%)
48. Suspect nr: 0=low, 10=high
49. Maximum FWS: suspect = 0
50. Maximum SWS HS: suspect = 0
51. Maximum SWS LS: suspect = 1
52. Maximum FL Yellow HS: suspect = 3
53. Maximum FL Yellow LS: suspect = 0
54. Maximum FL Orange HS: suspect = 1
55. Maximum FL Red HS: suspect = 1
56. Maximum FL Red LS: suspect = 1
57. SWS HS: PMT level is 54
58. SWS LS: PMT level is 48
59. FL Yellow HS: PMT level is 87
60. FL Yellow LS: PMT level is 68
61. Fl Orange: PMT level is 93
62. FL Red HS: PMT level is 116
63. FL Red LS: PMT level is 81

-------------------------- Warnings info --------------------------
1.09 Warning: This (default) low block size of 4kB in CytoUSB will decrease the effective analysis volume
1.09.1 Solution - Increase block size memory if the total particle rate is high enough (but prevent time outs)
1.21 Warning: Last calibration of sample pump towards analysis date was more than 90 days. (24-Feb-2021)
1.21.1 Solution - Check if the pumped analysis volume is the real volume by weighing
1.24 Warning: SWS LS: Maximum is 221 mV if HS is around 4500 mV and too high.
1.24.1 Solution - Put LS PMT lower. Maximum LS around 50 mV (if HS is around 4500 mV).
1.24 Warning: SWS LS: HS-LS ratio is 62 and too low.
1.24.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.24 Warning: FL Yellow LS: HS-LS ratio is 49 and too low.
1.24.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.24 Warning: FL Red LS: Maximum is 132 mV if HS is around 4500 mV and too high.
1.24.1 Solution - Put LS PMT lower. Maximum LS around 50 mV (if HS is around 4500 mV).
1.24 Warning: FL Red LS: HS-LS ratio is 56 and too low.
1.24.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.27 Warning: FL Yellow HS : Nr of particles with signal height <10 mV is high (72 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: FL Orange HS : Nr of particles with signal height <10 mV is high (65 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.25 Warning: Suspected particles data blocks found!
1.29.1: Maximum FL Yellow HS: suspect = 3
1.29.11 Solution - Particle rate too high?
1.29.21 Solution - Trigger too sensitive?
1.29.31 Solution - Details look at 'DATA DIAGNOSIS' in 'Check CytoSense-Diagnosis-Meta Data'
Disclaimer
Any use of the provided data and results or information provided by this website is on full own risk and responsibility. Those who gave access to this website or those who provided the results represented on the website cannot be held responsible for any damage or consequences that could arise from the use of this information. This LIVE system is empowered by the Rijkswaterstaat, CytoBuoy BV and Thomas Rutten Projects. TRP Copyright 2021