PhytoplanktonLIVE.com
Online automatic phytoplankton monitoring at several locations performed by flowcytometry (CytoSense-CytoSub)
< HOME  TO OVERVIEW  1 TO OVERVIEW  2 >

Live Results Markermeer
To overview 2
EasyClus check & Info of last file

----- Processed at : 26-Nov-2020 00:15:55 -----

1. The cytometric analysis is performed on machine Markermeer
2. The CytoUSB software used is CytoUSB Version: 5.8.4.8
3. The filename is CS2019-91 MW prot2 2020-11-26 00h03.cyz
4. The analysis is performed on 26-11-2020 time 00:03:27
5. The number of measured particles is 23152
6. The total concentration found (e.g. only SWS trigg.) is 955 particles/microliter
7. The concentration found (all used triggers) is 72 particles/microliter
8. The preconcentration (before analysis) found (all used triggers) is 72 particles/microliter
9. The flush time found (between samples) is 50 seconds
10. The effective analysis volume is 319.4225 microliter
11. The pumped volume is 321 microliter
12. The particle-rate is 1026 particles passing the laser beam/second
13. The used sample flow rate is 1.0746 microliter/second
14. The used block size memory is 4 kB
15. Trigger 1: SWS HS at threshold level 15 mV
16. Trigger 2: Maximum FL Red HS at threshold level 6
17. Temperature sensor PMT is : 128 C
18. Temperature sensor Sheath is : 9 C
19. Temperature sensor Sheath is : 9 C
20. Pressure sensor difference is : -288 mBar
21. Pressure sensor absolute is : 340 mBar
22. Sample pump 1: Last calibration of the sample pump was : 17-Feb-2020
23. Alignment check 1 by curvature detector is 0.99551 (1=perfect)
24. Alignment check 2 by curvature detector is 99% (100%=perfect)
25. Saturated signals (flattened peaks) occur when the dynamic range of the (HS)detector is reached
26. FWS: Nr of saturated signals is 5 (0% of 23152 measured particles)
27. FWS: Maximum signal height found is 14720 mV
28. FWS: Nr of particles with signal height <10 mV is high (47 part. (0 %))
29. SWS HS: Nr of saturated signals is 1 (0% of 23152 measured particles)
30. SWS HS: Maximum signal height found is 5824 mV
31. SWS HS: Nr of particles with signal height <10 mV is high (0 part. (0 %))
32. FL Yellow HS: Nr of saturated signals is 1 (0% of 23152 measured particles)
33. FL Yellow HS: Maximum signal height found is 5600 mV
34. FL Yellow HS: Nr of particles with signal height <10 mV is high (20630 part. (89 %))
35. FL Orange HS: Nr of saturated signals is 1 (0% of 23152 measured particles)
36. FL Orange HS: Maximum signal height found is 5312 mV
37. FL Orange HS: Nr of particles with signal height <10 mV is high (12564 part. (54 %))
38. FL Red HS: Nr of saturated signals is 6 (0% of 23152 measured particles)
39. FL Red HS: Maximum signal height found is 7360 mV
40. FL Red HS: Nr of particles with signal height <10 mV is high (5811 part. (25 %))
41. SWS HS: Nr of block shaped signals is 20 (0.086386%)
42. FWS: Nr of block shaped signals is 13 (0.056151%)
43. FL Red HS: Nr of block shaped signals is 12 (0.051831%)
44. FL Orange HS: Nr of block shaped signals is 4 (0.017277%)
45. FL Yellow HS: Nr of block shaped signals is 2 (0.0086386%)
46. Suspect nr: 0=low, 10=high
47. Maximum FWS: suspect = 0
48. Maximum SWS HS: suspect = 0
49. Maximum SWS LS: suspect = 0
50. Maximum FL Yellow HS: suspect = 3
51. Maximum FL Yellow LS: suspect = 0
52. Maximum FL Orange HS: suspect = 0
53. Maximum FL Red HS: suspect = 0
54. Maximum FL Red LS: suspect = 0
55. SWS HS: PMT level is 51
56. SWS LS: PMT level is 46
57. FL Yellow HS: PMT level is 87
58. FL Yellow LS: PMT level is 70
59. Fl Orange: PMT level is 96
60. FL Red HS: PMT level is 118
61. FL Red LS: PMT level is 80
62. IIF: Imaging in Flow pictures available. Nr of images is 251

-------------------------- Warnings info --------------------------
1.04 Warning: Your flush time (50 seconds) is quite small
1.04.1 Solution - Flush longer e.g. 80 sec.
1.09 Warning: This (default) low block size of 4kB in CytoUSB will decrease the effective analysis volume
1.09.1 Solution - Increase block size memory if the total particle rate is high enough (but prevent time outs)
1.12 Warning: Temperature sensor PMT is high. Inner temperature instrument is high
1.12.1 Solution - Shut laser off if not used, airco in instrument room
1.17 Warning: Last calibration of sample pump towards analysis date was more than 90 days. (17-Feb-2020)
1.17.1 Solution - Check if the pumped analysis volume is the real volume by weighing
1.20 Warning: SWS LS: Maximum is 336 mV if HS is around 4500 mV and too high.
1.20.1 Solution - Put LS PMT lower. Maximum LS around 50 mV (if HS is around 4500 mV).
1.20 Warning: SWS LS: HS-LS ratio is 49 and too low.
1.20.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.20 Warning: FL Yellow LS: HS-LS ratio is 128 and too high.
1.20.1 Solution - Put LS PMT higher. Ratio HS/LS should be around 100.
1.20 Warning: FL Red LS: Maximum is 109 mV if HS is around 4500 mV and too high.
1.20.1 Solution - Put LS PMT lower. Maximum LS around 50 mV (if HS is around 4500 mV).
1.20 Warning: FL Red LS: HS-LS ratio is 73 and too low.
1.20.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.23 Warning: FL Yellow HS : Nr of particles with signal height <10 mV is high (89 %)
1.23.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.23.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.23.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.23 Warning: FL Orange HS : Nr of particles with signal height <10 mV is high (54 %)
1.23.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.23.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.23.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.25 Warning: Suspected particles data blocks found!
1.25.1: Maximum FL Yellow HS: suspect = 3
1.25.1 Solution - Particle rate too high?
1.25.1 Solution - Trigger too sensitive?
1.25.1 Solution - Details look at 'DATA DIAGNOSIS' in 'Check CytoSense-Diagnosis-Meta Data'
Disclaimer
Any use of the provided data and results or information provided by this website is on full own risk and responsibility. Those who gave access to this website or those who provided the results represented on the website cannot be held responsible for any damage or consequences that could arise from the use of this information. This LIVE system is empowered by the Rijkswaterstaat, CytoBuoy BV and Thomas Rutten Projects. TRP Copyright 2020