Fytoplankton.nl
Online automatic phytoplankton monitoring at several locations performed by flowcytometry (CytoSense-CytoSub)
< HOME  TO OVERVIEW  1 TO OVERVIEW  2 >

Live Results Markermeer
To overview 2
EIJ_SWS15_FLRed6_auto_uls_phyto_600s 2019-11-21 08h02.cyz

----- Processed at : 21-Nov-2019 08:13:02 -----

1. The cytometric analysis is performed on machine Eijsden
2. The CytoUSB software used is CytoUSB Version: 5.8.2.17
3. The filename is EIJ_SWS15_FLRed6_auto_uls_phyto_600s 2019-11-21 08h02.cyz
4. The analysis is performed on 21-11-2019 time 08:02:49
5. The number of measured particles is 145
6. The total concentration found (e.g. only SWS trigg.) is 0 particles/microliter
7. The concentration found (all used triggers) is 0 particles/microliter
8. The preconcentration (before analysis) found (all used triggers) is 0 particles/microliter
9. The flush time found (between samples) is 130 seconds
10. The effective analysis volume is 3851.4789 microliter
11. The pumped volume is 2364 microliter
12. The particle-rate is 0 particles passing the laser beam/second
13. The used sample flow rate is 3.9382 microliter/second
14. The used block size memory is 4 kB
15. Trigger 1: SWS HS at threshold level 15 mV
16. Trigger 2: Maximum FL Red HS at threshold level 6 mV
17. Temperature sensor PMT is : 28 C
18. Temperature sensor Sheath is : 23 C
19. Temperature sensor Sheath is : 28 C
20. Pressure sensor difference is : -543 mBar
21. Pressure sensor absolute is : 350 mBar
22. Sample pump 1: Last calibration of the sample pump was : 13-Sep-2019
23. Alignment check 1 by curvature detector is 1.1534 (1=perfect)
24. Alignment check 2 by curvature detector is 16% (100%=perfect)
25. Saturated signals (flattened peaks) occur when the dynamic range of the (HS)detector is reached
26. FWS: Nr of saturated signals is 0 (0% of 145 measured particles)
27. FWS: Maximum signal height found is 2 mV
28. FWS: Nr of particles with signal height <10 mV is high (145 part. (100 %))
29. SWS HS: Nr of saturated signals is 0 (0% of 145 measured particles)
30. SWS HS: Maximum signal height found is 627 mV
31. SWS HS: Nr of particles with signal height <10 mV is high (1 part. (1 %))
32. FL Yellow HS: Nr of saturated signals is 0 (0% of 145 measured particles)
33. FL Yellow HS: Maximum signal height found is 268 mV
34. FL Yellow HS: Nr of particles with signal height <10 mV is high (29 part. (20 %))
35. FL Orange HS: Nr of saturated signals is 0 (0% of 145 measured particles)
36. FL Orange HS: Maximum signal height found is 196 mV
37. FL Orange HS: Nr of particles with signal height <10 mV is high (31 part. (21 %))
38. FL Red HS: Nr of saturated signals is 0 (0% of 145 measured particles)
39. FL Red HS: Maximum signal height found is 60 mV
40. FL Red HS: Nr of particles with signal height <10 mV is high (6 part. (4 %))
41. Suspect nr: 0=low, 10=high
42. Maximum FWS: suspect = 0
43. Maximum SWS HS: suspect = 0
44. Maximum FL Yellow HS: suspect = 0
45. Maximum FL Orange HS: suspect = 0
46. Maximum FL Red HS: suspect = 5
47. Maximum SWS LS: suspect = 0
48. Maximum FL Yellow LS: suspect = 4
49. Maximum FL Red LS: suspect = 0
50. SWS HS: PMT level is 55
51. FL Yellow HS: PMT level is 81
52. FL Orange HS: PMT level is 80
53. FL Red HS: PMT level is 100
54. SWS LS: PMT level is 39
55. FL Yellow LS: PMT level is 66
56. FL Red LS: PMT level is 74

-------------------------- Warnings info --------------------------
1.01 Warning: The number of saved particles in this analysis is quite low and
1.01 Warning: you might miss (statistically) bigger particles in your sample
1.01.1 Solution - Increase number of measured particles. Increase setted time OR after setted number of analyzed particles (in CytoUSB)
1.03 Warning: Your preconcentration differs more than 25% from the during analysis concentration
1.03.1 Solution - Carry over between samples? > Flush longer
1.03.2 Solution - Better homogenize samples during subsampling by a gentle stirrer
1.03.3 Solution - Colonies-filaments of cells break during analysis > stir slower
1.09 Warning: This (default) low block size of 4kB in CytoUSB will decrease the effective analysis volume
1.09.1 Solution - Increase block size memory if the total particle rate is high enough (but prevent time outs)
1.19 Warning: FWS-L and -R might indicate an air bubble problem 16% (100%=perfect)
1.19.1 Solution - Pinch valve to get rid of the air bubble or blockage by something different
1.20 Warning: SWS LS: HS-LS ratio is 38 and too low.
1.20.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.20 Warning: FL Yellow LS: HS-LS ratio is 999 and too high.
1.20.1 Solution - Put LS PMT higher. Ratio HS/LS should be around 100.
1.20 Warning: FL Yellow LS: HS-LS ratio is 999 and too high.
1.20.1 Solution - Put LS PMT higher. Ratio HS/LS should be around 100.
1.20 Warning: FL Red LS: HS-LS ratio is 999 and too high.
1.20.1 Solution - Put LS PMT higher. Ratio HS/LS should be around 100.
1.22 Warning: FWS: Biggest particles found is only 2 mV. Detector sensitivity might be too low.
1.22.1 Solution - Increase, set higher FWS PMT voltage in CytoUSB (make more sensitive)
1.23 Warning: FWS : Nr of particles with signal height <10 mV is high (100 %)
1.23.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.23.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.23.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.22 Warning: FL Yellow HS: Biggest particles found is only 268 mV. Detector sensitivity might be too low.
1.22.1 Solution - Increase, set higher FL Yellow HS PMT voltage in CytoUSB (make more sensitive)
1.22 Warning: FL Orange HS: Biggest particles found is only 196 mV. Detector sensitivity might be too low.
1.22.1 Solution - Increase, set higher FL Orange HS PMT voltage in CytoUSB (make more sensitive)
1.22 Warning: FL Red HS: Biggest particles found is only 60 mV. Detector sensitivity might be too low.
1.22.1 Solution - Increase, set higher FL Red HS PMT voltage in CytoUSB (make more sensitive)
1.25 Warning: Suspected particles data blocks found!
1.25.1: Maximum FL Red HS: suspect = 5
1.25.1 Solution - Particle rate too high?
1.25.1 Solution - Trigger too sensitive?
1.25.1 Solution - Details look at 'DATA DIAGNOSIS' in 'Check CytoSense-Diagnosis-Meta Data'
1.25.2: Maximum FL Yellow LS: suspect = 4
1.25.2 Solution - Particle rate too high?
1.25.2 Solution - Trigger too sensitive?
1.25.2 Solution - Details look at 'DATA DIAGNOSIS' in 'Check CytoSense-Diagnosis-Meta Data'
Disclaimer
Any use of the provided data and results or information provided by this website is on full own risk and responsibility. Those who gave access to this website or those who provided the results represented on the website cannot be held responsible for any damage or consequences that could arise from the use of this information. This LIVE system is empowered by Rijkswaterstaat, CytoBuoy BV and Thomas Rutten Projects. TRP Copyright 2020