Live Results FerryFan
To overview 2
EasyClus check & Info of last file

----- Processed at : 20-Apr-2022 15:21:38 -----

1. The cytometric analysis is performed on machine RWS Systeem 2
2. The CytoUSB software used is CytoUSB Version: 5.8.3.31
3. The filename is CS_2019_92_prot_1 2021-01-28 14h21.cyz
4. The analysis is performed on 28-01-2021 time 14:23:37
5. The number of measured particles is 8996
6. The total concentration found (e.g. only SWS trigg.) is 149 particles/microliter
7. The concentration found (all used triggers) is 149 particles/microliter
8. The preconcentration (before analysis) found (all used triggers) is 149 particles/microliter
9. The flush time found (between samples) is 130 seconds
10. The effective analysis volume is 60.5193 microliter
11. The pumped volume is 60.6 microliter
12. The particle-rate is 150 particles passing the laser beam/second
13. The used sample flow rate is 1.0101 microliter/second
14. The used block size memory is 4 kB
15. Trigger 1: SWS HS at threshold level 15 mV
16. Trigger 2: not used at threshold level -999
17. Temperature sensor PMT is : 32.1 C
18. Temperature sensor Sheath is : 31.6 C
19. Temperature sensor Sheath is : 30.6 C
20. Temperature sensor System is : 26.4 C
21. Pressure sensor difference is : -226 mBar
22. Pressure sensor absolute is : 171 mBar
23. Sample pump 1: Last calibration of the sample pump was : 26-Okt-2020
24. Alignment check 1 by curvature detector is 1.1865 (1=perfect)
25. Alignment check 2 by curvature detector is 35% (100%=perfect)
26. Saturated signals (flattened peaks) occur when the dynamic range of the (HS)detector is reached
27. FWS: Nr of saturated signals is 1 (0% of 8996 measured particles)
28. FWS: Maximum signal height found is 6592 mV
29. FWS: Nr of particles with signal height <10 mV is high (4591 part. (51 %))
30. SWS HS: Nr of saturated signals is 1 (0% of 8996 measured particles)
31. SWS HS: Maximum signal height found is 7104 mV
32. SWS HS: Nr of particles with signal height <10 mV is high (0 part. (0 %))
33. FL Yellow HS: Nr of saturated signals is 0 (0% of 8996 measured particles)
34. FL Yellow HS: Maximum signal height found is 2208 mV
35. FL Yellow HS: Nr of particles with signal height <10 mV is high (8977 part. (100 %))
36. FL Orange HS: Nr of saturated signals is 0 (0% of 8996 measured particles)
37. FL Orange HS: Maximum signal height found is 2032 mV
38. FL Orange HS: Nr of particles with signal height <10 mV is high (8945 part. (99 %))
39. FL Red HS: Nr of saturated signals is 0 (0% of 8996 measured particles)
40. FL Red HS: Maximum signal height found is 1936 mV
41. FL Red HS: Nr of particles with signal height <10 mV is high (8653 part. (96 %))
42. SWS HS: Nr of block shaped signals is 16 (0.17786%)
43. FWS: Nr of block shaped signals is 3 (0.033348%)
44. Suspect nr: 0=low, 10=high
45. Maximum FWS: suspect = 1
46. Maximum SWS HS: suspect = 1
47. Maximum SWS LS: suspect = 2
48. Maximum FL Yellow HS: suspect = 0
49. Maximum FL Yellow LS: suspect = 4
50. Maximum FL Orange HS: suspect = 0
51. Maximum FL Red HS: suspect = 0
52. Maximum FL Red LS: suspect = 0
53. SWS HS: PMT level is 56
54. SWS LS: PMT level is 46
55. FL Yellow HS: PMT level is 85
56. FL Yellow LS: PMT level is 68
57. Fl Orange: PMT level is 77
58. FL Red HS: PMT level is 110
59. FL Red LS: PMT level is 91
60. IIF: Imaging in Flow pictures available. Nr of images is 304

-------------------------- Warnings info --------------------------
1.01 Warning: The number of saved particles in this analysis is quite low and
1.01 Warning: you might miss (statistically) bigger particles in your sample
1.01.1 Solution - Increase number of measured particles. Increase setted time OR after setted number of analyzed particles (in CytoUSB)
1.09 Warning: This (default) low block size of 4kB in CytoUSB will decrease the effective analysis volume. (Only older CytoSenses)
1.09.1 Solution - Increase block size memory if the total particle rate is high enough (but prevent time outs) OR set to 'auto'
1.21 Warning: Last calibration of sample pump towards analysis date was more than 90 days. (26-Okt-2020)
1.21.1 Solution - Check if the pumped analysis volume is the real volume by weighing
1.23 Warning: FWS-L and -R might indicate an air bubble problem 35% (100%=perfect)
1.23.1 Solution - Pinch valve to get rid of the air bubble or blockage by something different
1.24 Warning: SWS LS: Maximum is 135 mV if HS is around 4500 mV and too high.
1.24.1 Solution - Put LS PMT lower. Maximum LS around 50 mV (if HS is around 4500 mV).
1.24 Warning: SWS LS: HS-LS ratio is 46 and too low.
1.24.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.24 Warning: FL Red LS: HS-LS ratio is 23 and too low.
1.24.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.27 Warning: FWS : Nr of particles with signal height <10 mV is high (51 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: FL Yellow HS : Nr of particles with signal height <10 mV is high (100 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: FL Orange HS : Nr of particles with signal height <10 mV is high (99 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.27 Warning: FL Red HS : Nr of particles with signal height <10 mV is high (96 %)
1.27.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.27.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.27.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.25 Warning: Suspected particles data blocks found!
1.29.1: Maximum FL Yellow LS: suspect = 4
1.29.11 Solution - Particle rate too high?
1.29.21 Solution - Trigger too sensitive?
1.29.31 Solution - Details look at 'DATA DIAGNOSIS' in 'Check CytoSense-Diagnosis-Meta Data'
Disclaimer
Any use of the provided data and results or information provided by this website is on full own risk and responsibility. Those who gave access to this website or those who provided the results represented on the website cannot be held responsible for any damage or consequences that could arise from the use of this information. This LIVE system is empowered by the Rijkswaterstaat, CytoBuoy BV and Thomas Rutten Projects. TRP Copyright 2020