Live Results Eijsden
To overview 2
EIJ_SWS15_FLRed6_auto_phyto_600s 2020-11-23 08h01.cyz

----- Processed at : 23-Nov-2020 08:12:46 -----

1. The cytometric analysis is performed on machine Eijsden
2. The CytoUSB software used is CytoUSB Version: 5.8.3.42
3. The filename is EIJ_SWS15_FLRed6_auto_phyto_600s 2020-11-23 08h01.cyz
4. The analysis is performed on 23-11-2020 time 08:02:31
5. The number of measured particles is 82
6. The total concentration found (e.g. only SWS trigg.) is 2 particles/microliter
7. The concentration found (all used triggers) is 0 particles/microliter
8. The preconcentration (before analysis) found (all used triggers) is 0 particles/microliter
9. The flush time found (between samples) is 50 seconds
10. The effective analysis volume is 2407.6604 microliter
11. The pumped volume is 2724 microliter
12. The particle-rate is 10 particles passing the laser beam/second
13. The used sample flow rate is 4.5388 microliter/second
14. The used block size memory is 4 kB
15. Trigger 1: SWS HS at threshold level 15 mV
16. Trigger 2: Maximum FL Red HS at threshold level 6
17. Temperature sensor PMT is : 29 C
18. Temperature sensor Sheath is : 25 C
19. Temperature sensor Sheath is : 29 C
20. Pressure sensor difference is : -345 mBar
21. Pressure sensor absolute is : 319 mBar
22. Sample pump 1: Last calibration of the sample pump was : 02-Jul-2020
23. Alignment check 1 by curvature detector is 1.2559 (1=perfect)
24. Alignment check 2 by curvature detector is 95% (100%=perfect)
25. Saturated signals (flattened peaks) occur when the dynamic range of the (HS)detector is reached
26. FWS: Nr of saturated signals is 1 (1% of 82 measured particles)
27. FWS: Maximum signal height found is 9823 mV
28. FWS: Nr of particles with signal height <10 mV is high (3 part. (4 %))
29. SWS HS: Nr of saturated signals is 5 (6% of 82 measured particles)
30. SWS HS: Maximum signal height found is 5000 mV
31. SWS HS: Nr of particles with signal height <10 mV is high (0 part. (0 %))
32. FL Yellow HS: Nr of saturated signals is 0 (0% of 82 measured particles)
33. FL Yellow HS: Maximum signal height found is 573 mV
34. FL Yellow HS: Nr of particles with signal height <10 mV is high (35 part. (43 %))
35. FL Orange HS: Nr of saturated signals is 0 (0% of 82 measured particles)
36. FL Orange HS: Maximum signal height found is 331 mV
37. FL Orange HS: Nr of particles with signal height <10 mV is high (54 part. (66 %))
38. FL Red HS: Nr of saturated signals is 0 (0% of 82 measured particles)
39. FL Red HS: Maximum signal height found is 38 mV
40. FL Red HS: Nr of particles with signal height <10 mV is high (75 part. (91 %))
41. FL Yellow HS: Nr of block shaped signals is 9 (10.9756%)
42. Suspect nr: 0=low, 10=high
43. Maximum FWS: suspect = 0
44. Maximum SWS HS: suspect = 0
45. Maximum FL Yellow HS: suspect = 0
46. Maximum FL Orange HS: suspect = 0
47. Maximum FL Red HS: suspect = 0
48. Maximum SWS LS: suspect = 0
49. Maximum FL Yellow LS: suspect = 0
50. Maximum FL Red LS: suspect = 0
51. SWS HS: PMT level is 53
52. FL Yellow HS: PMT level is 78
53. FL Orange HS: PMT level is 77
54. FL Red HS: PMT level is 97
55. SWS LS: PMT level is 25
56. FL Yellow LS: PMT level is 62
57. FL Red LS: PMT level is 70

-------------------------- Warnings info --------------------------
1.01 Warning: The number of saved particles in this analysis is quite low and
1.01 Warning: you might miss (statistically) bigger particles in your sample
1.01.1 Solution - Increase number of measured particles. Increase setted time OR after setted number of analyzed particles (in CytoUSB)
1.03 Warning: Your preconcentration differs more than 25% from the during analysis concentration
1.03.1 Solution - Carry over between samples? > Flush longer
1.03.2 Solution - Better homogenize samples during subsampling by a gentle stirrer
1.03.3 Solution - Colonies-filaments of cells break during analysis > stir slower
1.04 Warning: Your flush time (50 seconds) is quite small
1.04.1 Solution - Flush longer e.g. 80 sec.
1.09 Warning: This (default) low block size of 4kB in CytoUSB will decrease the effective analysis volume
1.09.1 Solution - Increase block size memory if the total particle rate is high enough (but prevent time outs)
1.17 Warning: Last calibration of sample pump towards analysis date was more than 90 days. (02-Jul-2020)
1.17.1 Solution - Check if the pumped analysis volume is the real volume by weighing
1.20 Warning: FL Yellow LS: HS-LS ratio is 1 and too low.
1.20.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.20 Warning: FL Yellow LS: HS-LS ratio is 2 and too low.
1.20.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.20 Warning: FL Red LS: HS-LS ratio is 1 and too low.
1.20.1 Solution - Put LS PMT lower. Ratio HS/LS should be around 100.
1.22 Warning: FL Orange HS: Biggest particles found is only 331 mV. Detector sensitivity might be too low.
1.22.1 Solution - Increase, set higher FL Orange HS PMT voltage in CytoUSB (make more sensitive)
1.23 Warning: FL Orange HS : Nr of particles with signal height <10 mV is high (66 %)
1.23.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.23.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.23.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.22 Warning: FL Red HS: Biggest particles found is only 38 mV. Detector sensitivity might be too low.
1.22.1 Solution - Increase, set higher FL Red HS PMT voltage in CytoUSB (make more sensitive)
1.23 Warning: FL Red HS : Nr of particles with signal height <10 mV is high (91 %)
1.23.1 Solution - Increase, set higher trigger threshold (to prevent measuring noise)
1.23.2 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.23.3 Solution - Clean sheath, clean cuvette, clean tubing? (noise can be introduced by dirty walls)
1.24 Warning: FL Yellow HS: A relative large amount of particles are (rather) block shaped (11%)
1.24.1 Solution - Decrease, set lower particle sample rate. Maybe caused by an overload of particles/ noise in your sample
1.24.2 Solution - Decrease, set lower FL Yellow HS PMT voltage in CytoUSB (make less sensitive)
Disclaimer
Any use of the provided data and results or information provided by this website is on full own risk and responsibility. Those who gave access to this website or those who provided the results represented on the website cannot be held responsible for any damage or consequences that could arise from the use of this information. Powered by TRP © 2020